FOCUS LIMIT

This distance is approximate value and the focus operate from the setting

value.

CAUTION: Avoid continuous, 24-hour use of the auto focus. This will shorten the

lifespan of the lens.

• WB (White Balance) CONTROL

WB SETUP

MODE : AWB
R GAIN : ---
B GAIN : ---
SAVE AND EXIT(ESC TO CANCEL)


MODE

AWB / WAWB / INDOOR / OUTDOOR / MANUAL

AWB

Computes the white balance value output using color information

from the entire screen automatically. (2500 to 9500 °K)

WAWB

Wide range auto white balance mode (1800 to 10500 °K)

INDOOR

Indoor white balance mode

OUTDOOR

Outdoor white balance mode

MANUAL

Manual mode, you can change R and B Gain manually.

RGAIN

0 ~ 255

BGAIN

0 ~ 255

RGAIN / BGAIN modes are controllable only in MANUAL Mode.

• AE CONTROL

AE SETUP

MODE : MANUAL
DSS LIMIT : ---
GAIN : MIN
BRIGHT : 024
SHUTTER : 1/60
FLICKERLESS : ---
BACK LIGHT : OFF
WDR : ---
WDR LEVEL : ---
NIGHT SHOT : AUTO
SAVE AND EXIT(ESC TO CANCEL)

MODE

AE1 / AE2 / SHUTTER PRIO / MANUAL

AE1

Auto exposure mode1 (Use to normal surroundings: indoor)

AE2

Auto exposure mode2 (Use to high brightness surroundings: outdoor)

SHUTTER PRIO Variable Shutter speed, Auto Gain
MANUAL

Variable Shutter speed, Gain

DSS LIMIT

OFF / x2 / x4 / x8 / x16 / x32 / x64 / x128 / x256 / x512

GAIN

MIN / LOW / MID / HIGH

BRIGHT

10 ~ 50

SHUTTER

1/60(50), 1/100(120), …, 1/10000, 1/100000

FLICKERLESS

OFF / ON

BACK LIGHT

OFF / BLC / HLC (NOTE: When BLC or HLC, WDR will be disabled.)