Examples, Example 1, Example 2 – Grass Valley 2200 User Manual
Page 112: Examples -22, Example 1 -22 example 2 -22

5-22
Section 5 Ñ Digital Effects Interface
Examples
The following are examples of switcher messages to and from the DPM. All values
are in hex. The semi-colon after 2 or more bytes is just used as a separator to give
the name of that Þeld and any other explanatory information. (Values are in
hexadecimal)
Example 1
DPM -> switcher, RETURN_CODE:
00 01
; Version
00 11
; Msg token, RETURN_CODE
00 00
; Return Id
00 04
; Data Size
00 00 00 16
; Header checksum
00 00 00 0F
; Return code
Example 2
Switcher -> DPM, UNSUBSCRIBE
00 01
; Version
00 0a
; Msg token, UNSUBSCRIBE
00 00
; Return Id
00 18
; Data Size
00 00 00 23
; Header checksum
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ; 16 bytes rqstAddr
00 00
; Rqst Id
00 00
; Serial number
00 03
; Service Id, PARAMETER_SERVICE
00 04
; flags, CLEAR_SUBSCRIPTIONS