Valid Effects Addresses for the Recall E-MEM to Switcher command are:
EFFECTS ADDRESS
ASSIGNMENTS
00
PGM-PST Mix System
01
Mix/Effects 1 System
02
Mix/Effects 2 System
03
Mix/Effects 3 System
04
Downstream Keyer (DSK)
05 Background
(BKGD)
06 Miscellaneous
07 DPM
1
08 DPM
2
09 DPM
3
0A DPM
4
0B
All enabled levels
FF
All specified levels
1
NOTE:
Must specify 0B effects address when recalling a 300 Style Master
E-MEM effect.
The editor may recall a speciÞc Effects Address or may recall all levels currently
enabled on the control panel. If the Effects Address is FF then the levels to be
recalled are speciÞed in a 2-byte Bit-Mask
Mode Byte
2
The Mode byte allows an E-MEM recall with Effects Dissolve, Auto Recall, and
Run, either separately or together. The Mode byte takes precedence over the
Switcher button tallies. The mode byte looks at three operations:
¥
Force the Auto Run/Auto Recall/Effects Dissolve operation
¥
Inhibit the Auto Run/Auto Recall/Effects Dissolve operation
¥
Operate according to current Switcher panel settings
1. Not supported in Version 5.0 and earlier
2. In Version 5.0 and earlier, the value of the mode byte was ignored and treated as though all bits were zero.
That is to say, the E-MEM Register will be recalled and the action performed will be according to what was
learned into the E-MEM Register and the current panel state.