Mode byte, Mode byte -32 – Grass Valley 2200 User Manual

Page 56

Advertising
background image

3-32

Section 3 Ð Editor Interface Commands

Valid Effects Addresses for the Recall E-MEM to Switcher command are:

EFFECTS ADDRESS

ASSIGNMENTS

00

PGM-PST Mix System

01

Mix/Effects 1 System

02

Mix/Effects 2 System

03

Mix/Effects 3 System

04

Downstream Keyer (DSK)

05 Background

(BKGD)

06 Miscellaneous

07 DPM

1

08 DPM

2

09 DPM

3

0A DPM

4

0B

All enabled levels

FF

All specified levels

1

NOTE:

Must specify 0B effects address when recalling a 300 Style Master

E-MEM effect.

The editor may recall a speciÞc Effects Address or may recall all levels currently
enabled on the control panel. If the Effects Address is FF then the levels to be
recalled are speciÞed in a 2-byte Bit-Mask

Mode Byte

2

The Mode byte allows an E-MEM recall with Effects Dissolve, Auto Recall, and
Run, either separately or together. The Mode byte takes precedence over the
Switcher button tallies. The mode byte looks at three operations:

¥

Force the Auto Run/Auto Recall/Effects Dissolve operation

¥

Inhibit the Auto Run/Auto Recall/Effects Dissolve operation

¥

Operate according to current Switcher panel settings

1. Not supported in Version 5.0 and earlier
2. In Version 5.0 and earlier, the value of the mode byte was ignored and treated as though all bits were zero.

That is to say, the E-MEM Register will be recalled and the action performed will be according to what was
learned into the E-MEM Register and the current panel state.

Advertising
This manual is related to the following products: