3.5.4 Removing the plinth panels
3.5.5 Removing the exhaust air filter in the base
Depending on the production version, the plinth panel of
the Sunny Central 100 consists of one unit or two units.
Identical plinth panels are installed in both production
versions.
1. Loosen the screws on the edges of the plinth panel.
2. Remove the plinth panel by pulling it forward.
☑ The plinth panel is removed.
1. Loosen the thumb nut at the filter in the base of the
switch cabinet.
2. Remove the filter.
☑ The filter can now be cleaned.