5 Installation and Uninstallation Procedure

YASKAWA ELECTRIC TOBP C730600 55D 1000-Series Option PS-A10 Installation Manual

17

Installation Method A

DANGER! Electrical Shock Hazard. Disconnect all power to the unit and wait at least the amount of time

specified on the unit front cover safety label. After all indicators are off, measure the DC bus voltage to

confirm safe level, and check for unsafe voltages before servicing. The internal capacitor remains charged

after the power supply is turned off.

NOTICE: Damage to Equipment. Observe proper electrostatic discharge procedures (ESD) when handling

the option, unit, and circuit boards. Failure to comply may result in ESD damage to circuitry.

1.

Shut off power to the unit, wait the appropriate amount of time for voltage to
dissipate, then remove the connector cover by pushing on the connector tab and

sliding the cover towards the top of the unit as indicated by the arrow in

Figure 6

.

Figure 6

Figure 6 Remove the Connector Cover

2.

Pull the loose end of the connection cable out of the option.

Figure 7

Figure 7 Pull Out the Connection Cable