Z1000u bypass quick start procedure, Hoa keypad tutorial, Page 11 of 37 – Yaskawa Z1000U HVAC Matrix Bypass User Manual

Page 11: Auto

Advertising
background image

YASKAWA TOEP YAIZ1D01A Z1000U Matrix Bypass Quick Start Procedure

Z1000U Bypass
Quick Start Procedure

Page 11

of 37

6.1 Review this tutorial to become familiar with HOA Keypad operation before proceeding.

F2

F1

ESC

M

M

AUTO

OFF

ENTER

RESET

ALM

DIGITAL OPERATOR JVOP-183

HAND

F2

F

F2

F2

F2

F2

F2

F2

F2

F2

2

2

F

F

F1

F1

F1

F1

F1

F1

F1

F1

F1

1

A

A

A

A

AU

AU

AU

AU

AU

AU

U

U

U

AU

U

A

O

O

O

O

O

O

O

O

O

O

OF

OF

F

O

F

NTE

ENTE

ENTE

NT

ENTE

NT

NTE

E

E

E

NTE

RE

RE

RE

RE

E

RE

R

RE

S

S

S

S

S

S

S

S

E

E

E

E

E

E

E

E

E

E

E

E

E

E

ET

ET

E

E

E

HAND

HAN

HAN

HAND

AND

AND

AND

N

HAN

ES

ES

ESC

ESC

ESC

ESC

ESC

ESC

ESC

C

C

C

C

12

11

9

8

1

2

3

10

4

5 6

7

No.

Display

Key or Indicator Name

Function

1

Function F1 (RLY)

Selects Drive Test Mode
Note: Applies specifi cally to drives confi gured with 3-contactor. Pressing the
F1 (RLY) key places the drive in Drive Test Mode. Power is applied to the drive
in the bypass mode.

Function F2 (BYP/DRV)

Toggles selection between Bypass Mode and Drive Mode.

2

ESC

Returns to the previous display.

Moves the cursor one space to the left.

In Drive Mode, repeatedly pressing this button will return to the Frequency
Reference display.

In Bypass Mode, repeatedly pressing this button will return to the UB-01
“Bypass Current” display.

During parameter entry, allows aborting the current edited value and exits
the parameter editing mode.

3

RESET

Moves the cursor to the right.

Resets the bypass or drive to clear a fault situation

Certain drive conditions may require pressing the OFF key before the
RESET key will clear a fault..

4

AUTO

Selects AUTO mode.

5

Up Arrow

Scrolls up to display the next item, selects parameter numbers, and
increments setting values.

6

Down Arrow

Scrolls down to display the previous item, selects parameter numbers, and
decrements setting values.

7

OFF Key

If the drive was operating the motor, the motor will stop according to the
stopping method selected in b1-03. If the bypass was operating the motor, the
bypass contactor opens and the motor coasts to a stop.

8

ENTER

Enters parameter values and settings.

Selects a menu item to move between displays.

9

HAND

Selects HAND mode.

10

AUTO

AUTO Light

Lit or fl ashing while the drive is in AUTO mode.

11

HAND Light

Lit while the drive is in HAND mode.

12

ALARM Light

Flashing: Indicates Alarm (minor fault)

Solid: Indicates Fault (major fault)