3 conditions of acceptability – Yaskawa V1000 Finless Type User Manual

Page 10

Advertising
background image

3 Conditions of Acceptability

10

YASKAWA ELECTRIC TOBP C710606 21E YASKAWA AC Drive - V1000 Finless Installation Guide

Table 2 Recommended Heatsink Plate Thermal Compounds

Spread the required amount of thermal compound over the clean heatsink plate. Firmly press

the V1000 finless drive against the metal panel and hold it in place against the heatsink plate

for a few seconds. Wipe away any excess thermal compound from around the heatsink plate

edges.

Figure 3

Figure 4 Application of Thermal Compound

Note: Surface milling of the metal panel to within 0.05 mm (0.0019 in) flatness is required if use of

less thermal compound is desired.

Ensure the V1000 finless drive is firmly pressed against the metal panel for a few seconds to

ensure proper thermal transfer.

Drive Heatsink Plate Installation Screw Size and Tightening
Torque

Screw size and torque specifications for heatsink plate installation screws that hold the drive

to a metal back panel are listed in

Table 3

.

Table 3 Screw Size and Tightening Torque

Manufacturer

Type

Model

Required Amount

Shin-Etsu Chemical Inc.

Oil-based
compound

G746

100 to 250

μm (0.0039 to 0.0098 in)

(Varies in accordance with the flatness
of the metal panel.)

Dow Corning Toray Inc.

Silicone compound
for heat dissipation

SC4471CV

Voltage Class

Model

CIMR-V†

Screw Size

Tightening Torque

Nxm (ft-lbf)

Single-Phase 200 V class

BA0001 ~ BA0012

M4

1.0 to 1.3 (0.74 to 0.96)

Metal panel

Thermal compound

Heatsink plate

Installation
screws

V1000 Finless

Advertising