3 Conditions of Acceptability

12

YASKAWA ELECTRIC TOBP C710606 21E YASKAWA AC Drive - V1000 Finless Installation Guide

Table 5 Correct Installation Spacing

NOTICE: Do not install V1000 Finless drives using the Side-by-Side method available in standard V1000

drive models. Improper drive cooling may result in damage to the drive. Install V1000 Finless drives with a

minimum side-by-side clearance of 30 mm (1.18 in).

Ambient Temperature Derating

Parameters L8-12 (Ambient Temperature Setting) and L8-35 (Installation Method Selection)

must be set according to the installation conditions if the ambient temperature is higher than

35

°C. Refer to

Figure 5

for drive derating according to ambient temperature.

Parameter L8-12 = 40

°C (default). The setting range is -10 to 50°C.

Operating the V1000 Finless drive between -10 and 35

°C allows 100% continuous current

without derating. Drive operation between 35 and 50

°C requires drive derating according to

Figure 5

.

The drive can be used with 100% rating between -10 and 50

°C ambient temperature if the

airflow around the unit is 0.5 m/s or more. In this case set L8-35 = 0 (Installation method =

IP20 standard drive).

Figure 4

Figure 5 Ambient Temperature and Drive Derating

Voltage Class

Drive Model

CIMR-V†

Side Clearance (a)

mm / (in)

Single-Phase 200 V Class

BA0001 to BA0012

30 / (1.18)

Three-Phase 200 V Class

2A0001 to 2A0069

Three-Phase 400 V Class

4A0001 to 4A0038

0

Rating

100%

80%

35°C

L8-35 = 3 (default)
Finless/External heatsink

50°C

L8-12

Ambient

Temperature

Setting

L8-35 = 0

surrounding

airflow of 0.5 m/s