Table 7, 3 conditions of acceptability – Yaskawa V1000 Finless Type User Manual

Page 14

Advertising
background image

3 Conditions of Acceptability

14

YASKAWA ELECTRIC TOBP C710606 21E YASKAWA AC Drive - V1000 Finless Installation Guide

Heavy Duty

Table 7 Drive Watt Loss (Heavy Duty Rating)

200 V Single-PhaseClass

Model

CIMR-V…BA

<1> Carrier frequency is set to 10 kHZ.

<2> Carrier frequency is set to 8 kHZ.

0001

<1>

0002

<1>

0003

<1>

0006

<1>

0010

<2>

0012

<2>

Rated Output Current

(A)

0.8 1.6 3.0 5.0 –

8.0 11.0 –

Generated

Heat Loss

Heatsink

Plate (W)

4.3 7.9 16.1 33.7 –

54.8 70.7 –

Internal (W) 7.4 8.9 11.5 16.8 –

25.9 34.1

Total (W) 11.7 16.8 27.6 50.5 –

80.7 104.8 –

200 V Three-Phase Class

Model

CIMR-V…2A

0001

<1>

0002

<1>

0004

<1>

0006

<1>

0008

<1>

0010

<2>

0012

<2>

0018

<2>

0020

<2>

0030

<2>

0040

<2>

0056

<2>

0069

<2>

Rated Output Current

(A)

0.8 1.6 3.0 5.0 6.9 8.0 11.0 14.0 17.5 25.0 33.0 47.0 60.0

Generated

Heat Loss

Heatsink

Plate (W)

4.3 7.9 16.1 27.4 48.7 54.8 70.7 92.6 110.5 213.3 239.5 347.6 473.9

Internal (W) 7.3 8.8 11.5 15.9 22.2 23.8 30.0 38.8 43.3 68.1 79.6 113.8 156.7

Total (W) 11.6 16.7 27.6 43.3 70.9 78.6 100.7 131.4 153.8 281.4 319.1 461.4 630.6

400 V Three-Phase Class

Model

CIMR-V…4A

0001

<2>

0002

<2>

0004

<2>

0005

<2>

0007

<2>

0009

<2>

0011

<2>

0018

<2>

0023

<2>

0031

<2>

0038

<2>

Rated Output Current

(A)

1.2 1.8 3.4 4.8 –

5.5 7.2 –

9.2 14.8 18.0 24.0 31.0

Generated

Heat Loss

Heatsink

Plate (W)

19.2 28.9 42.3 70.7 –

81.0 84.6 –

107.2 166.0 207.1 266.9 319.1

Internal (W) 11.4 14.9 17.9 26.2 –

30.7 32.9 –

41.5 61.7 75.0 102.1 115.4

Total (W) 30.6 43.8 60.2 96.9 – 111.7 117.5 –

148.7 227.7 282.1 369.0 434.5

Advertising