3 Conditions of Acceptability

YASKAWA ELECTRIC TOBP C710606 21E YASKAWA AC Drive - V1000 Finless Installation Guide

9

Figure 2

Figure 3 Output of Heatsink Plate Temperature by Analog Output

Note: 1. Accuracy of the temperature reading may vary

±5 ºC between 50 and 100 ºC.

2. The heatsink temperature is affected by the ambient temperature. Never exceed the allowable maximum

heatsink plate temperature.

■

Drive Overheat Alarm (oH)

Use parameter L8-02 to cause the drive output an alarm when the heatsink plate exceeds the

specified temperature.
L8-03 determines the action taken by the drive when an oH alarm is triggered. Refer to the

V1000 Technical Manual for more details.

◆

Installation to Metallic Surface

The mating surface shall have the following properties:

• Surface flatness shall not exceed 0.2 mm across the entire mating surface.

• Surface roughness shall not exceed 25 S.

Note: A surface roughness of 25 S means “Ra” (average roughness) is not greater than 6.3 a and “Ry”

(maximum peak) is not greater than 25

μm.

◆

Thermal Compound

Apply a thermal compound between the heatsink plate and the mating surface. The thermal

compound assists in drive heat dissipation.
Yaskawa recommends the thermal compounds in

Table 2

.

0

Output Voltage㧔V㧕

10.0

9.0

5.0

90

50

100 Temperature(°C)