Table 6, 3 conditions of acceptability – Yaskawa V1000 Finless Type User Manual

Page 13

Advertising
background image

3 Conditions of Acceptability

YASKAWA ELECTRIC TOBP C710606 21E YASKAWA AC Drive - V1000 Finless Installation Guide

13

V1000 Finless Drive Watt Loss Thermal Characteristics

Normal Duty

Table 6 Drive Watt Loss (Normal Duty Rating)

Note: Carrier frequency is set to 2 kHz.

200 V Single-Phase Class

Model

CIMR-V…BA

0001 0002 0003 0006 – 0010 0012

Rated Output Current

(A)

1.2 1.9 3.3 6.0

9.6 12.0 –

Generated

Heat Loss

Heatsink

Plate (W)

5.0 7.6 14.6 30.1

51.7 61.3 –

Internal (W) 8.0 9.7 14.4 19.4

29.8 37.1

Total (W) 13.5 17.3 29.0 49.5

81.5 98.4

200 V Three-Phase Class

Model

CIMR-V…2A

0001 0002 0004 0006 0008 0010 0012 0018 0020 0030 0040 0056 0069

Rated Output Current

(A)

1.2 1.9 3.5 6.0 8.0 9.6 12.0 17.5 19.6 30.0 40.0 56.0 69.0

Generated

Heat Loss

Heatsink

Plate (W)

5.0 7.6 15.8 27.5 44.6 51.7 61.3 89.8 98.7 238.2 266.7 357.9 477.3

Internal (W) 8.0 9.5 13.6 17.2 24.0 25.8 30.4 44.1 46.3 85.8 108.6 145.2 185.8

Total (W) 13.0 17.1 29.4 44.7 68.6 77.5 91.7 133.9 145.0 324.0 375.3 503.1 663.1

400 V Three-Phase Class

Model

CIMR-V…4A

0001 0002 0004 0005 – 0007 0009

0011 0018 0023 0031 0038

Rated Output Current

(A)

1.2 2.1 4.1 5.4 –

6.9 8.8 –

11.1 17.5 23.0 31.0 38.0

Generated

Heat Loss

Heatsink

Plate (W)

10.0 18.5 30.5 44.5 –

58.5 63.7 –

81.7 181.2 213.4 287.5 319.2

Internal (W) 9.6 13.9 16.8 21.8 –

28.5 31.4 –

46.0 78.4 101.8 139.4 138.8

Total (W) 19.6 32.4 47.3 66.3 –

87.0 95.1 –

127.7 259.6 315.2 426.9 458.0

Advertising