6 selecting an external heatsink, Data required for heatsink selection, 6selecting an external heatsink – Yaskawa V1000 Finless Type User Manual

Page 21

Advertising
background image

YASKAWA ELECTRIC TOBP C710606 21E YASKAWA AC Drive - V1000 Finless Installation Guide

21

6 Selecting an External Heatsink

6

Selecting an External Heatsink

This section describes the selection of a suitable external heatsink when using a V1000

Finless drive.

Data Required for Heatsink Selection

The table below shows data that are needed to select a heatsink that suits drive and

application.

Symbol

Description

P

Loss

Drive heat loss

Refer to V1000 Finless Drive Watt Loss Thermal Characteristics on page 13

to check

the amount of heat loss from the heatsink plate of the drive.

T

HSP_max

Maximum heatsink plate temperature

This is the temperature at the surface of the heatsink plate. It can be monitored with U4-08. The
maximum allowable value depends on drive model.
CIMR-V†BA††††, CIMR-V†2A0001~0020, CIMR-V†4A0001~0011: 90

°C

CIMR-V†2A0030~0069, CIMR-V†4A0018~0038: 80

°C

T

Amb

External heatsink ambient temperature (air temperature around heatsink)

R

θ

HSP

Heatsink plate thermal resistance

This value is 0.05 K/W

R

θ

HSP-EHS

Thermal resistance between the heatsink plate and the external heatsink
Can be calculated by

A

th

Heat transfer area between drive heatsink plate and external heatsink
Note: Due to uneven heat generation across the heatsink plate (by arrangement
of internal components) the effective area for heat transfer is only ~70% of
heatsink plate area. This must be considered when calculating the thermal
resistance.
Refer to

Dimensions on page 16

for values of H and W to calculate the area of

the heatsink plate.

λ

Comp

Thermal conductivity of the heatsink thermal compound

d

Comp

Thickness of the thermal compound

R

θ

EHS

Thermal resistance of the external heatsink

R

θ

HSP-EHS

=

d

Comp

λ

comp

A

th

Advertising