Yaskawa J7 Drive User Manual
Page 46

5-11
Continued
Example 2 - Eight preset references
Programming:
n37 = 6, n38 = 7
and
n39 = 8
DIGITAL PRESET
S5
S4
S3
Selectable Reference
(2)
Open
Open
Open
n22
Open
Open
Closed
n23
Open
Closed
Open
n24
Open
Closed
Closed
n25
Closed
Open
Open
n26
Closed
Open
Closed
n27
Closed
Closed
Open
n28
Closed
Closed
Closed
5.11 FREQUENCY REFERENCE SELECTION
Example 1 - Four preset references
Programming:
n38 = 6
and
n39 = 7
DIGITAL PRESET
S5
S4
Selectable Reference
(2)
Open
Open
n22
Open
Closed
n23
Closed
Open
n24
Closed
Closed
(2)
The Selectable Reference is chosen from the following
list:
C.
Jog Reference
- See paragraph 5.12
D.
Frequency Reference via Serial
Communications
- See paragraph 5.14
REFERENCE SOURCE
PROGRAMMING
Digital Operator Speed Pot
n03
= 0
Digital Preset Reference parameter
n21
n03
= 1
Analog Input Terminal
FR
n03
= 2, 3, or 4
Serial Communications
n03
= 6