Name

Description

Run Fwd

Forward Run Command

0: Stop

1: Forward Run

Run Rev

Reverse Run Command

0: Stop

1: Reverse Run

Multi-Function Input 3

Terminal S3 Function Input

0: Terminal S3 Function (H1-03) OFF

1: Terminal S3 Function (H1-03) ON

Multi-Function Input 4

Terminal S4 Function Input

0: Terminal S4 Function (H1-04) OFF

1: Terminal S4 Function (H1-04) ON

Multi-Function Input 5

Terminal S5 Function Input

0: Terminal S5 Function (H1-05) OFF

1: Terminal S5 Function (H1-05) ON

Multi-Function Input 6

Terminal S6 Function Input

0: Terminal S6 Function (H1-06) OFF

1: Terminal S6 Function (H1-06) ON

Multi-Function Input 7

Terminal S7 Function Input

0: Terminal S7 Function (H1-07) OFF

1: Terminal S7 Function (H1-07) ON

External Fault

External Fault EF0

0: No External Fault (EF0)

1: External Fault (EF0)

Fault Reset

Fault Reset

0: No Fault Reset

1: Fault Reset

Multi-Function Digital

Output

Terminal MA/MB

0: MA/MB OFF

1: MA/MB ON

This function is enabled only when H2-01 is set to F.

Multi-Function

Photocoupler 1

Terminal P1

0: P1 OFF

1: P1 ON

This function is enabled only when H2-02 is set to F.

Multi-Function

Photocoupler 2

Terminal P2

0: P2 OFF

1: P2 ON

This function is enabled only when H2-03 is set to F.

Speed Reference

Speed Command

Sets drive speed reference.
Unit depends on o1-03.

Unit is not affected by Speed Scale SS.

Torque Reference [0.1%] Torque Reference [0.1%], not supported

Torque Compensation

[0.1%]

Torque Compensation [0.1%], not supported

Digital Inputs

MEMOBUS/Modbus (0x49). Monitor parameter U1-10

NetRef

Network sets reference

NetCtrl

Network sets control

Analog Output 1

MEMOBUS/Modbus (0x0007)

Analog Output 2

MEMOBUS/Modbus (0x0008)

Digital Outputs

MEMOBUS/Modbus (0x0009)

Programmable Bytes

Contains the data to be written to the MEMOBUS/Modbus address defined in the given parameter. A value of 0 in the given

parameter means it is not used, therefore the value received for this given parameter will not be written to any MEMOBUS/

Modbus register. If the PPA is Input Assembly 166, then any errors occurring during a write will be flagged.

Refer to High

Speed/Torque Status Input (Vendor Specific Yaskawa Electric (YE) Assy) - 166 (0xA6) on page 38

for details.

8 Output Assemblies (Drive Consumes)

30