Name

Description

Ready

Drive Ready

0: Not Ready

1: Ready

Ctrl from Net

Status of Run command from Network

0: Run command is not from network

1: Run command is from network

Ref from Net

Status of Speed reference from Network

0: Speed reference is not from network

1: Speed reference is from network

At Speed

Speed Agree

0: No Speed Agree

1: Speed actual at speed reference

Drive State

Contains the value from the Control Supervisor (Class 0x29) Instance 1 Attribute 6.

Speed Actual

Actual Drive Speed

Monitors drive output frequency.

Speed actual data: Output frequency x 2

SS

(SS: Speed scale)

Setting range: 0 to 0xFFFF

For example, when output frequency of 1024 with a speed scale of 2:

Speed actual data = 1024 x 2

2

= 4096 = 0x1000

Unit depends on o1-03.

Torque Actual

Output Torque, not supported

u

MEMOBUS/Modbus Message Input (Vendor Specific Yaskawa Electric (YE) Assy) - 150
(0x96)

Input Instance

Word

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

150

0

0

Function Code

1

Register Number (High Byte)

1

2

Register Number (Low Byte)

3

Register Data (High Byte)

2

4

Register Data (Low Byte)

Note:

This is a paired assembly (100/150).

Table 11 Reply Mapping – 150

Byte

Write Success

Read Success

Write Failure

Read Failure

Invalid Function Code Function Code

Equals Zero

0

0x10

0x03

0x90

0x83

Function Code Or-ed with

0x80

0

1

Output Assembly

Register Number

(High Byte)

Output Assembly

Register Number

(High Byte)

Output Assembly

Register Number

(High Byte)

Output Assembly

Register Number

(High Byte)

Output Assembly

Register Number

(High Byte)

0

2

Output Assembly

Register Number

(Low Byte)

Output Assembly

Register Number

(Low Byte)

Output Assembly

Register Number

(Low Byte)

Output Assembly

Register Number

(Low Byte)

Output Assembly

Register Number

(Low Byte)

0

3

0

Read Data

(High Byte)

0

0

0

0

4

0

Read Data (Low Byte)

Error Code

Error Code

1

0

Table 12 Error Replies – 150

Error Code

Description

0x01

Invalid Function Code

0x02

Invalid Register Number

0x21

Upper/Lower Limit Error

0x22

Option generated busy event. The MEMOBUS/Modbus requested operation is in the process loop but the drive is not done.

Writing “Enter” when drive is running.

Attempt to write data that is read only.

Attempt to write a parameter when drive is running.

During a CPF03 event attempting to write to registers other than A1-00 to A1-05, E1-03, o2-04.

0x23

Attempting to write during a drive undervoltage (Uv) event.