Name

Description

Multi-Function Digital

Output

Terminal MA/MB

0: MA/MB OFF

1: MA/MB ON

This function is enabled only when H2-01 is set to F.

Multi-Function

Photocoupler 1

Terminal P1

0: Terminal P1 OFF

1: Terminal P1 ON

Multi-Function

Photocoupler 2

Terminal P2

0: Terminal P2 OFF

1: Terminal P2 ON

Motor Speed

Monitor parameter U1-05

Torque Reference

Not supported

PG Count Value

Contained MEMOBUS/Modbus Address

Frequency Command

Monitor parameter U1-01

Output Frequency

Actual Drive Speed

Monitors drive output frequency.

Unit depends on o1-03.

Unit is not affected by Speed Scale SS.

Output Current

Actual Output Current

Monitors drive output current.

Unit is 0.01 A

Unit is not affected by Current Scale CS.

Drive Terminal A1 Input MEMOBUS/Modbus (0x46)

Monitor parameter U1-13

Main DC Voltage

Main Circuit DC Voltage

Monitor parameter U1-07

Error Code

U2-01 converted using fault code table

F7-33 Alarm Code

Programmable: MEMOBUS/Modbus (0x7F)

F7-35 Terminal A2 Input Programmable: MEMOBUS/Modbus (0x4F)

Monitor parameter U1-14

F7-36 Drive Terminal

S1 to S7

Programmable: MEMOBUS/Modbus (0x49)

Monitor parameter U1-10

F7-37 Terminal A3 Input Programmable: MEMOBUS/Modbus (0x50)

F7-38 PG Count Value

(CH 2)

Programmable: MEMOBUS/Modbus (0xF1)

Serial interface Control Response

9 Input Assemblies (Drive Produces)