Setting the station run time, Master valve operation – Irritrol IBOC-Plus User Manual
Page 14
12
SETTING THE STATION RUN TIME
A station is assigned to a program when it is given a run time (from one
minute to 23 hours and 59 minutes) in that program. Each station is
limited to one run time assignment per program. However, stations can
be assigned to one, two or three programs and have a different run time
assignment in each.
To set the run time for each station:
1. Turn the function dial to
STATION WATER TIMES/MASTER VALVE
.
2. Select Program
A
,
B
or
C
with the
PROGRAM
button.
3. Press the
NEXT
button to select the station number you wish to set
(if other than the one displayed).
4. Use the +/
ON
and/or –/
OFF
button(s) to display the desired station
run time minutes (0–59).
5. Press the
NEXT
button select hours.
6. Use the +/
ON
and/or –/
OFF
button(s) to display the desired station
run time hours (0–23).
Note: The factory setting for each station is “Off.” If the station
has a run time and you wish to remove it from this program, use
the +/
ON
and/or –/
OFF
button(s) to select 0 minutes and 0 hours .
7. Repeat steps 3 through 6 to set a run time for each station you
wish to assign to the selected program.
8. Repeat steps 2 through 5 for each program as necessary.
9. When finished, return the function dial to
AUTO RUN.
MASTER VALVE OPERATION
The IBOC Plus enables master valve operation to be selected
independently for each watering program. By default, the master valve
circuit is activated for each watering program.
Note: If a master valve is not installed, its operation must be disabled
to prevent an “Open MV” fault from occurring.
To select master valve operation:
1. Turn the function dial to
STATION WATER TIMES/MASTER VALVE
.
2. Select Program
A
,
B
or
C
with the
PROGRAM
button.
3. Press the
NEXT
button repeatedly until “Master Valve” is displayed.
4. Press the +/
ON
or –/
OFF
button to display the operation of the
master valve for the selected program.
5. Repeat steps 2 through 4 for each program as necessary.
6. When finished, return the function dial to
AUTO RUN.
Programming the Controller