Options 10, Options 11 – Irritrol MC-E User Manual
Page 31
1
Options 10
Option 10 is used in conjunction with the Start Sensor and Program 1. With Option 10 set to “PGM 1 Start=ON” and the
Start Sensor is activated, Program 1 will turn on immediately. Program 1 will repeat the cycle continuously until the start
sensor is deactivated. All other programs will not be affected and will activate as scheduled.
Application Example: Activate dust control program with wind sensor, allow other programs to continue.
Activate Option 10
Step 1 – Place the Function Dial to the Options position. Press the
or
button until Option 10 is displayed.
Step 2 – Use the
or
button to activate or deactivate Option 10. When activated, program 1 will start when the
start sensor is triggered.
If program 1 has no value, the controller will function normally.
Step 3 – Return the Function dial to AUTO/RUN
position to exit Options.
If Option 9 is activated, it will take precedence over Option 10. (See “Option 9” on page 30.)
Options 11
Option 11 is used to activate or deactivate the master valve during station delays.
Application Example: Water well recovery between station operations where the well needs to refill from ground water.
The MV/Pump circuit would be OFF during the delay period.
Activate Option 11
Step 1 – Place the Function Dial to the Options position. Press the
or
button until Option 11 is displayed.
Step 2 – Use the
or
button to toggle Master Valve function from ON or OFF during station delays.
Step 3 – Return the Function dial to AUTO/RUN
position to exit Options.