Set flow sensor model, Set flow unit, Read/learn station flow value – Irritrol MC-E User Manual

Page 38

Advertising
background image



Set Flow Sensor Model

Flow Sensor Data Table

Step 1 – Place the Function dial to the FLOW

SENSING

position. Enable

flow sensing if its disabled.

Step 2 – While in the K Value/Sensor Size

screen, select the flow sensor size
code by pressing the

button.

Use the Flow Sensor table below to
find your specific size code.
Example: If using Sensor Model
TFS-075, press the

button until

the S value in the display equals 75
(S=75).

Set Flow Unit

Step 1 – Place the Function dial to the FLOW SENSING

position. Enable flow sensing if its disabled.

Step 2 – Press the

button to change the flow unit. Press the

button repeatedly until the desired flow unit is

displayed (GPM = Gallons per Minute, CFM = Cubic Feet per Minute, CMH = Cubic Meter per Hour,

LPM = Liter per Minute or PPS = Pulses per Second).

If the sensor you choose is not represented on the chart, use “Unknown Flow Sensor” size code “00”. The flow

unit for “Unknown Flow Sensor” can only be set to PPS.

Read/Learn Station Flow Value

Step 1 – Place the Function dial to the FLOW SENSING

position. Enable flow sensing if its disabled.

Step 2 – Verify that all flow parameters are set, then press the

button to read/learn each of the station’s actual

flow. It will read/learn the station’s flow value until the flow delay time expires. The default flow delay is one

minute. During “Learn Flow” each station will be displayed with the flow that the sensor is measuring.

To learn the flow value of a specific station, enter the two digit station number and press the

button.

To learn the flow value of a group of stations, enter the two digit station number of the 1st station, the two digit
station number of the last station and press the

button. The MC-E will sequentially read the flow value for

each station in the group.

Step 6 – To review each station flow parameters, press the

button. MC-E will sequentially display each of the

station’s flow parameters.

Flow Sensor Model

K Value

Offset

GPM

L/Sec

Size

Code

Pipe

Size

Unkown Flow Sensor

00

Unkown

1

0

PPS

PPS

TFS-050

50

1/2’’

0.07800

0.9

1.2 – 12

0.1 – 0.8

TFS-075

75

3/4’’

0.15630

0.9

2.7 – 28

0.2 – 1.8

TFS-100

100

1’’

0.26112

1.2

5.0 – 50

0.3 – 3.2

TFS-150 or 228PV15xx-xxxx

150

1.5’

1.69900

-0.3160

5 – 100

0.3 – 6.3

TFS-200 or 228PV20xx-xxxx

200

2.0’’

2.84290

0.14350

10 – 200

0.6 – 12.6

TFS-300 or 228PV30xx-xxxx

300

3.0’’

8.30900

0.22700

20 – 300

1.3 – 18.9

TFS-400 or 228PV40xx-xxxx

400

4.0’’

13.74283

0.23707

40 – 500

2.5 – 31.5

250BR0700x-xxxx

7

3/4’’

0.43680

0.56800

250BR1000x-xxxx

10

1’’

0.39740

0.26180

0.25 Liters Per Pulse

11

0.25 L/P

1

0

0.50 Liters Per Pulse

12

0.50 L/P

1

0

1 Liter Per Pulse

13

1 L/P

1

0

2.5 Liters Per Pulse

14

2.5 L/P

1

0

5 Liters Per Pulse

15

5 L/P

1

0

10 Liters Per Pulse

16

10 L/P

1

0

25 Liters Per Pulse

17

25 L/P

1

0

50 Liters Per Pulse

18

50 L/P

1

0

100 Liters Per Pulse

19

100 L/P

1

0

250 Liters Per Pulse

20

250 L/P

1

0

500 Liters Per Pulse

21

500 L/P

1

0

1000 Liters Per Pulse

22

1000 L/P

1

0

Advertising