Rain Sensor Installation (Purchased Separately)

IMPORTANT! The INHIBIT SENSOR is designed for a

normally closed rain sensor. The wire jumper must be present at the

terminals if a sensor is not connected.

Step 1 – Route the rain sensor cable into the controller terminals.
Step 2 – Remove the wire jumper from the INHIBIT and SENSOR

terminals for the 18 stations or more models and

INHIB.SEN and SEN.COM for the 12 stations or less

models. Refer to the provided rain sensor installation

guide for wiring instructions and connect accordingly.

The INHIBIT SENSOR will operate on any

Function Dial position settings.

Start Sensor Installation (Purchased Separately)

IMPORTANT! The START SENSOR input is designed for

a normally open sensor and works in conjunction with Options 9

and 10. When the start sensor is activated, the MC-E controller will

immediately activate Program 1 providing Option 10 is activated.

Program 1 will continue to repeat the cycle until the start sensor is

deactivated. The activation of the start sensor will not affect any

other programs. Option 9 works similarly by turning ON program 8,

however all other programs are turned OFF.

Step 1 – Route the sensor connection cable through the bottom of

the controller cabinet and into the controller terminals.

Step 2 – Refer to the provided sensor installation guide for wiring

instructions.

The START SENSOR will operate on any

Function Dial position except for RAIN OFF.

VALVE

COMMON

VALVE

COMMON

VALVE

COMMON

MASTER

VALVE

YEL RED

VALVE

COMMON

GND

1

3

5

7

9

11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41

2

4

6

8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42

1

3

5

7

9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47

2

4

6

8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

INHIBIT SENSOR

START SENSOR

FLOW SENSOR

VALVE

COMMON

VALVE

COMMON

VALVE

COMMON

MASTER

VALVE

YEL RED

VALVE

COMMON

GND

1

3

5

7

9

11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41

2

4

6

8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42

1

3

5

7

9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47

2

4

6

8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

INHIBIT SENSOR

START SENSOR

FLOW SENSOR

Models with 12 Stations or Less

Models with 18 Stations or More

SEN.COM START SEN.

START SENSOR

Advertising