blueplanet Operating and Installation Instructions 1502x - 2502x

Operation

4.4 Level 1 menu – Display

mode

The display menu is shown once the blueplanet inverter starts
up. Measured values and all of the counters are displayed here.
Key “1” is used to navigate through the individual menu items.

Display of inverter type

Generator voltage and current

Grid voltage, current and power

Daily peak capacity

Temperature inside unit

Counter

yield

Yield

today

Total yield

(Total) economy of CO

2

Counter oper. hours

Operating hours today

Total operating hours

Figure 4: Display mode menu

Explanation of the individual menu items:

Display of inverter type
Inverter type - blueplanet 1502x/2502x display

Generator voltage and current
The current voltage and current of the PV solar generator that
is connected to the inverter.

Grid voltage, current and power
The current line voltage, line current, and the power that is
currently being fed into the power grid.

Daily peak capacity
The respective day’s peak power that was fed into the grid for
a short time.

Temperature inside unit
Displays the current heat sink temperature. If the unit becomes
too hot, the unit will reduct power output or switch off.

Counter yield
This counter totals all yields until it is reset. The customer can
confi gure the time periods for this counter, e.g. as a monthly
counter. The counter can be cleared in confi guration mode
“Clear yield”.

Yield today
The power that has been fed into the grid during the current
day. This value resets to zero each morning.

Total yield
The power that has been fed into the grid since installation
of the inverter. The initial value can be set in confi guration
mode.

(Total) economy of CO

2

Shows the CO

2

savings of this PV installation compared to the

German electricity mix. The CO

2

savings are calculated from the

total yield counter and can also be cleared with this counter.

Counter oper. hours
This counter totals all yields until it is reset again. The cus-
tomer can confi gure the time periods for this counter, e.g. as
a monthly counter. It can be cleared in confi guration mode
“Clear yield”.

Operating hours today
Today’s hours of operation. As soon as the inverter is in stand-
by mode (i.e. when LED (1) lights up), the running time is added
up.

Total operating hours
The hours of operation since installation of the inverter. As
soon as the inverter is in stand-by mode (i.e. when LED (1)
lights up), the running time is added up.

4.5 Level 2 menu –

Confi guration mode

ACTION

To access confi guration mode, press both keys at the same
time. The software version display appears. Pressing key
“1” now switches to the next menu item and changes can
be made in the respective menu item by pressing key “2”.
The setting value increases each time key “2” is pressed.
If the maximum value has been reached, the value returns
to the minimum setting choice.