Action, 4 level 1 menu – display mode, 5 level 2 menu – confi guration mode – KACO blueplanet 1502xi User Manual
Page 6
 
Page 8
blueplanet Operating and Installation Instructions 1502x - 2502x
Operation
4.4 Level 1 menu – Display
mode
The display menu is shown once the blueplanet inverter starts 
up. Measured values and all of the counters are displayed here. 
Key “1” is used to navigate through the individual menu items.
Display of inverter type
Generator voltage and current
Grid voltage, current and power
Daily peak capacity
Temperature inside unit
Counter
yield
Yield
today
Total yield
(Total) economy of CO
2
Counter oper. hours
Operating hours today
Total operating hours
Figure 4: Display mode menu
Explanation of the individual menu items:
Display of inverter type
Inverter type - blueplanet 1502x/2502x display
Generator voltage and current
The current voltage and current of the PV solar generator that 
is connected to the inverter.
Grid voltage, current and power
The current line voltage, line current, and the power that is 
currently being fed into the power grid.
Daily peak capacity
The respective day’s peak power that was fed into the grid for 
a short time.
Temperature inside unit
Displays the current heat sink temperature. If the unit becomes 
too hot, the unit will reduct power output or switch off.
Counter yield 
This counter totals all yields until it is reset. The customer can 
confi gure the time periods for this counter, e.g. as a monthly 
counter. The counter can be cleared in confi guration mode 
“Clear yield”.
Yield today 
The power that has been fed into the grid during the current 
day. This value resets to zero each morning. 
Total yield
The power that has been fed into the grid since installation 
of the inverter. The initial value can be set in confi guration 
mode.
(Total) economy of CO
2
Shows the CO
2
savings of this PV installation compared to the
German electricity mix. The CO
2
savings are calculated from the
total yield counter and can also be cleared with this counter.
Counter oper. hours 
This counter totals all yields until it is reset again. The cus-
tomer can confi gure the time periods for this counter, e.g. as 
a monthly counter. It can be cleared in confi guration mode 
“Clear yield”.
Operating hours today
Today’s hours of operation. As soon as the inverter is in stand-
by mode (i.e. when LED (1) lights up), the running time is added 
up.
Total operating hours 
The hours of operation since installation of the inverter. As 
soon as the inverter is in stand-by mode (i.e. when LED (1) 
lights up), the running time is added up.
4.5 Level 2 menu –
Confi guration mode
ACTION
To access confi guration mode, press both keys at the same 
time. The software version display appears. Pressing key 
“1” now switches to the next menu item and changes can 
be made in the respective menu item by pressing key “2”. 
The setting value increases each time key “2” is pressed. 
If the maximum value has been reached, the value returns 
to the minimum setting choice.