Operation
Defi ne the initial value of the total yield
Use this menu setting to defi ne or reset the intial value of the 
total yield of the inverter. 
Select the RS485 address
If the RS485 interface is activated, you can reach the address 
setting by pressing key “1”. By pressing key “2”, the address 
can be set in a consecutive manner from 1 to 32.
The address then jumps back to 1. The RS485 interface is used 
to communicate with the KACO pro
LOG, watchDOG or
other monitor. If several inverters are connected to a KACO 
pro
LOG, watchDOG or other monitor each address may
only be used once. It is possible to monitor 32 blueplanet inver-
ters with one KACO pro
LOG. To connect the RS485 interface,
please contact your installer.
S0 interface pulse rate
The S0 interface is designed as a galvanically isolated transistor 
output. This interface is designed according to “DIN 43864 – 
Current interface for transmitting pulses from a pulsing meter 
to a tariff metering device”.
The S0 interface pulse rate can be chosen in three unit inter-
vals: 500, 1,000 and 2,000 pulses/kWh. 
To connect the S0 interface, please contact your installer.
ACTION
Settings are saved only upon exiting confi guration mode. 
If 2 minutes elapse without a key being pressed, the 
confi guration mode is automatically exited. The confi guration 
mode can also be immediately exited by pressing both keys. 
As a confi rmation, “Settings saved” appears on the display. 
The settings are now permanently saved in the blueplanet 
inverter.
Quick start
The inverter can also be started up without any waiting period 
for the purpose of testing or for the purpose of acceptance by 
your power supply company.
If the inverter is already feeding into the grid, this menu item 
is not available.
If there is insuffi cient solar generator power, the inverter stops 
feeding into the grid after a short period of time.
Software version
Serial number
Current country
Language selection
Clear the grid-feed counter
Defi ne the initial value of the total yield
Select the RS485 address
 S0 interface
 
Quick start
Figure 5: Confi guration mode menu
Explanation of the individual menu 
items:
Software version
The current software version is displayed here.
Serial number
Display of the serial number specifi c to the unit.
Current country
Display of the current country settings.
Language selection
The language of the display interface can be selected here.
Clear the grid-feed counter
When you clear the grid-feed counter, all counters (Counter 
yield and Counter oper. hours) are reset to zero. 
To clear the counters, select “Yes” with key “2”, and confi rm 
your selection by pressing the “1” key. The required code is 
“2” and is entered using key “2”. By means of an additional 
confi rmation with key “1”, all counter are cleared. The display 
“Grid-feed counter cleared!” confi rms that the counters have 
been cleared.
“Counter yield” and “Counter oper. hours” can be cleared sepa-
rately from the other counters. These counters are cleared in the 
confi guration menu using key 2 and the code 2. ”Counter yield” 
and “Counter oper. hours” are always cleared together.