Authorised electrician

6

Installation and startup

DANGER

Risk of fatal injury from fire or explosions
Fire caused by flammable or explosive materials in the vicinity of the device can lead to serious

injuries.

›

Do not install the device in areas where there is a risk of explosion.

›

Do not install the device in the vicinity of highly flammable materials.

›

Do not install the device over a battery.

›

Do not install in the vicinity of electrolytes and corrosive aerosols.

6.1

Installation location

Installation space

•

Restrict access by unauthorised personnel,

•

As dry as possible, well ventilated, and it must be possible to convey the waste heat away from the device

•

Unobstructed air circulation,

•

Accessible from the front and sides without requiring additional resources,

•

Do not install the device or the corresponding batteries in a damp area,

•

Protect against direct sunlight and direct water contact,

•

For easy operation, ensure during installation that the display is slightly below eye level.

•

Observe local regulations when installing in combination with a battery.

Wall

•

With sufficient load-bearing capacity,

•

Accessible for installation and maintenance,

•

Made from heat-resistant material (up to 90 °C),

•

Flame resistant,

•

Minimum clearances at the installation and assembly location. (See Figure 7 on page 19)

NOTE

Access by maintenance personnel for service
Any additional costs arising from unfavourable structural or mounting conditions shall be billed to

the customer.

CAUTION

Risk of chemical burns!

›

Disconnecting a live DC connection can cause a dangerous arc which could result in hot and corro-

sive particles arising from the battery This could cause irreversible health damage.

›

Only trained and qualified electrical personnel are permitted to remove connections from battery

cells in line with appropriate procedures and safety precautions.

›

Observe the safety instructions from the battery manufacturer.