Using an AGS Module: Operation

Figure 7-2, AGS PORT, CONTROL, METER, and TECH Menu Maps

Port-specific METER displays:

TECH

02 Port Vers/RTR=3.0
1 5.1 2 ---- 3 5.3
4 ---- 5 ---- 6 ----
ALL Read TECH

CTRL

03 Gen Control
OFF

P3 Read AGS CTRL

OFF
ON
AUTO

AGS Home Screen

Auto Gen Start

Gen Ready 0.0Hrs

25.0VDC TS Open

P3 AGS Home

04B DC Volts to AGS

25.0 VDC

P3 Read AGS METER

04C Gen Run Time
3.0 Hours

P3 Read AGS METER

04E Since Gen Run
2 Days

P3 Read AGS METER

04D AGS Temp
TS Open

P3 Read AGS METER

04A AGS Status
Gen Ready

P3 Read AGS METER

R

R

R

04F Since 100% Days
2 Days

P3 Read AGS METER

04G Gen Hour Meter
10 Hours

P3 View AGS METER

R

R

R

P

04G Gen Hour Meter
0 Hours

P3 Reset AGS METER

2 secs

METER

AC In

Start SOC

Fault Gen Run

Gen Cooldown

Start Temp

Fault MaxRn

Gen Off

Start Test

Fault SOC

Gen Ready

Start Time Daily

Fault Test

Gen Warmup

Start Topoff

Fault Time Daily

Manual Run

Start VDC

Fault Temp

No AGS Comm

Start 100% SOC

Fault Topoff

Quiet Time

Fault Amp

Fault VDC

Start Amp

Fault Exercise

Fault 100% SOC

Start Exercise

Unknown ?##?

PORT

P

04B DC Volts to AGS
1 25.0 2 ---- 3 ----
4 ---- 5 ---- 6 ----

ALL Read AGS METER

04C Gen Run Time
1 3.0 2 ---- 3 ----
4 ---- 5 ---- 6 ----
ALL Read AGS METER

Read Only

displays

04A AGS Status
1 Redy 2 ---- 3 ----
4 ---- 5 ---- 6 ----
ALL Read AGS METER

R

R

R

04D AGS Temp
1 TS 0 2 ---- 3 ----
4 ---- 5 ---- 6 ----
ALL Read AGS METER

04E Since Run Days
1 2 2 ---- 3 ----
4 ---- 5 ---- 6 ----
ALL Read AGS METER

R

R

03 Timers
04 AGS Meters
05 BMK Meters

ALL Select METER

04F Since 100% Days
1 2 2 ---- 3 ----
4 ---- 5 ---- 6 ----
ALL Read AGS METER

04G Gen Hour Meter
1 10 2 ---- 3 ----
4 ---- 5 ---- 6 ----
ALL Reset AGS METER

04G Gen Hour Meter
1 10 2 ---- 3 ----
4 ---- 5 ---- 6 ----
ALL View AGS METER

R

ALL Ports METER displays:

2 secs

P

METER

03 AccPort Versions
1 ---- 2 ---- 3 ----
4 ---- 5 ---- 6 ----

ALL Read TECH

R

R

04 Fault History
Press SELECT

ALL View TECH

P

P

R

H2 AGS Fault History
Fault Temp 0.0Hrs
27.6VDC 87F
P3 2 12:10A AGS

H1 AGS Fault History
Fault VDC 1.0Hrs
25.0VDC TS Cold
P3 0 8:15P AGS

04 Fault History
AGS Faults
Clear All Faults
ALL Select TECH

7.2.5

ME-RTR Router’s AGS Menu Maps

This section provides the AGS menu maps available from your router. Refer to Appendix A in the

back of this manual for a glossary of abbreviations that may appear on the router’s LCD display.
Note: The router enables you to access AGS METER button info from two sources: 1) View AGS

meter info from the specifi c port to which the AGS is connected (via the AGS Home screen), 2)

You can also access meter information for all ports (via the System Home screen).
Note: When applicable, battery voltage defaults and ranges are shown for a 24-volt battery (12-

volt systems divide by 2; 48-volt systems multiply by 2).