Initial installation, Qualified installers only – Enviro Westport C-10381 User Manual

Page 19

Advertising
background image

1

2

3

4

5

View showing fully

open restrictor plate

View showing fully

closed restrictor plate

1

2

3

4

5

Figure 22: Restrictor plate settings.

The ENVIRO WESTPORT has been designed with a built in restrictor

plate. The restrictor is designed to enhance flame appearance when

installing this unit with vertical chimneys as well as installations with

longer horizontal vent applications. It does this by controlling the

amount of air moving through the vent pipe.
Figure 23 shows the vent restrictor position required, relative to the

length of vent pipe. Longer vertical vent lengths necessitate greater

restriction; position 1 is open and position 5 is maximum restriction

(refer to Figure 22). To avoid injury, it is best to make this adjustment

when the fireplace is cool or use welder’s gloves or oven mitts.

19

v

ent

c

onFiguRations

anD

R

estRictoR

s

ettings

:

Figures 23 & 24 show the range of venting options, they show possible vent configurations if the unit is

top vented (see Figure 23) or rear vented (see Figure 24), for vertical and horizontal terminations, any

layout that remains within the shaded area is acceptable. Having the fewest number of elbows is ideal,

as they tend to disrupt air movement. Using 45˚ elbows is preferable to using 90˚ elbows. Also, a shorter

vent system will perform better than a longer one.

Initial Installation

QUALIFIED INSTALLERS ONLY

Figure 23. Possible Vent Configurations for Top Vented;

Vertical and Horizontal Terminations.

To access vent restrictor remove the valve

cover plate from the right rear corner of the

unit by undoing the two fastening screws.
Loosen the ¼” hex head screw and adjust to

the correct setting.
Slide the hex head screw to the next setting

and re-tighten the screw to secure in place.
The numbers in this chart represent the actual

vent restrictor settings. Although the numbers

do not appear on the unit use this as a guide

to follow.
Wait for unit to warm up to operating

temperature to ensure proper and clean

burning unit.

Figure 24. Possible Vent Configurations for Rear

Vented; Vertical and Horizontal Terminations.

Note: 0,0 in Figures 23 & 24 represent

the outlet of the flue collar elbow.