Operating instructions – Enviro Westport C-10381 User Manual

Page 7

Advertising
background image

7

2. Start the pilot by pressing the gas control knob and turning it to PILOT.

While holding the gas control knob in, press the piezo ignitor several

times until the pilot light starts. Hold the gas control knob in for 30

seconds. Check that the pilot has fully engulfed the thermocouple

assembly (see Figure 3).

3. Start the main burner by turning the gas control knob to ON and then

turn the rocker switch to ON. Check that all burner ports have flame.

4. Leak test all gas joints again.

Thermopile

Thermocouple

Figure 3. Pilot Flame

Operating Instructions

P

iLot

L

ight

:

1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out

for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints

with soapy water. NEVER USE OPEN FLAME FOR LEAK TESTING.

a

iR

s

hutteR

:

The air shutter is controlled with the primary air adjustment rod located behind the gas valve shown in

Figure 4.
The air shutter allows the amount of air coming into the fireplace to be adjusted in order to accommodate

different climates and venting arrangements. Start the pilot and then the burner. Make sure the pilot

flame is burning normally and none of the burner ports are plugged. Let the fireplace burn for roughly

fifteen (15) minutes and then examine the flames, compare the flames to Figure 61.

Gas valve

regulator

Gas valve

Primary air

adjustment rod

Figure 4: Gas Valve In Place on Unit.

The ideal flame will be blue at the base and light

orange above. The flames should be of medium

height. If the flames look like this, no venturi

adjustment is needed. If the flames are fairly

short and mostly blue, the fireplace is getting

too much air. Therefore, the air shutter should

be closed slightly until the correct flames are

achieved. Flames that are very orange, with tall,

dark, stringy tips, are not getting enough air.

Open the venturi until the flames clean up. If the

venturi is opened, or closed all the way, and the

correct flames cannot be attained, turn off the

gas and contact the dealer.

Warning: Incorrect venturi adjustment may lead

to improper combustion, which is a safety hazard.

Contact the dealer if there is any concern about the

venturi adjustment.

Table 1: Venturi Information.

Natural Gas

Propane

Venturi Setting

1

/

16

” min.

3

/

16

” min.

Advertising
This manual is related to the following products: