Initial installation, Qualified installers only e – Enviro Westport C-10381 User Manual

Page 33

Advertising
background image

33

Figure 51: Gas Control Valve and Optional Thermostat Wiring.

Initial Installation

QUALIFIED INSTALLERS ONLY

e

LectRicaL

R

equiRements

F

oR

g

as

v

aLve

anD

o

PtionaL

b

LoweR

:

The ENVIRO WESTPORT will operate without electrical power. This model has a millivolt gas control,

which uses the pilot flame to generate enough electricity to operate the main burners. The appliance

when equipped with an optional blower must be electrically connected and grounded in accordance with

local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE

Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL ELECTRICAL CODE

ANSI / NFPA 70 in the U.S.

Fan

White

Black

Fan

temperature

sensor

White

Black

Fan

controller

Power

Supply

Figure 52. Wiring Diagram For Fan Control.

Table 8. Recommended Thermostat

Wire Size.

Wire Size

Max. Length

14 gauge

100 ft (30.48 m)

16 gauge

60 ft (18.29 m)

18 gauge

40 ft (12.00 m)

20 gauge

25 ft (7.62 m)

22 gauge

18 ft (5.49 m)

COOL / HEAT
PROGRAM

DOWN

UP

70 ° F

70 ° F

ON

OF

F

Optional

Remote

Control

ON/OFF/Remote

Thermostat Switch

Purple

Thermocouple

Blue

Thermopile

Grey

Inlet

Pressure

Tap

Gas Control

Valve

Manifold

Pressure Tap

Pilot Adjustment

Screw

Optional

Wall Switch

Optional

Thermostat

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause

improper and dangerous operation. Verify proper operation after servicing.
WARNING: Electrical grounding instructions. This appliance is equipped with a three-prong (grounding)

plug for your protection against shock hazard, and must be plugged directly into a properly grounded

three-prong outlet.
DO NOT cut or remove the grounding prong from this plug.

Advertising