Initial installation – Enviro Westport C-10381 User Manual

Page 27

Advertising
background image

27

Firebox Top

Flue Collar

Adapter

Undo four ¼"

screws that

hold flue collar

elbow to unit.

Figure 40: Step 3 of Converting Top Vented into

Rear Vented.

Figure 41: Step 4 of Converting Top

Vented into Rear Vented.

i

nstaLLation

oF

R

eaR

v

enteD

a

PPLiance

:

Siding

Exterior wall

Drywall

Vent pipe

Inside finished collar

Wall thimble

Minimum vent terminal 36"

(91.4cm) high snorkel kit.

Figure 42: Installation for Rear Vented;

30,000 Btu/hr.

2. Remove the four (4) ¼” screws that hold the flue collar elbow to the unit body (see Figure 40).
3. Carefully remove the elbow being sure not to damage the gasket that is glued to the flue collar elbow,

it seals the flue to the firebox.

4. Turn the elbow to the rear vent position and re-fasten with the screws removed in step 2 (see Figure

41).

Place the unit into position.
Attach a small section of pipe on the unit and mark exterior wall

where vent would pass through the wall.
Cut a 10” (25.4 cm) minimum hole in the wall to maintain

clearances to combustibles. Frame hole as shown in Figure 26.
Install a wall thimble.
Install interior finished collar.
Install the vent section through the wall.
THIS UNIT MUST BE VENTED WITH A 36” (91 cm) SNORKEL KIT

IF UNIT IS RATED FOR 30,000 Btu/hr NG and 26,000 Btu/hr LP.
Seal around the vent terminal to the structure using a non

hardening mastic.
Also refer to i

nitial

i

nStallation

- v

ent

c

onfiGurationS

and

r

eStrictor

S

ettinGS

.

Initial Installation

QUALIFIED INSTALLERS ONLY