Installation instructions, Ab c – MCZ Vivo 80 Pellet Comfort Air - 2012 User Manual
Page 12

A
B
C
10
2-INSTALLATION INSTRUCTIONS
COMBUSTION AIR
During operation a certain amount of air is drawn from the room in which the product is installed and this air must be supplemented
through an air inlet.
The combustion air in this product is autonomously drawn directly from the grille on the pellet loading door. The 65 mm diameter pipe
supplied must be connected to the product and the door as shown in the figure.
The user can decide to draw the combustion air from outside, in which case, the pipe must be connected to the product and an external
air intake.
A - AIR INLET FROM THE PELLET LOADING DOOR
B - FLEXIBLE PIPE
C - PIPE CONNECTION TO THE PRODUCT
HOT AIR OUTLET DUCTING
The product can distribute the hot air by Forced Convection by means of a forced ventilation kit (supplied).
The product comes with two types of kits:
• Comfort Air Slim.
• Comfort Air Basic.
The main characteristics of the two kits are:
• Kit Comfort Air Slim - 12 multi diffuser, 60 mm diameter ducting and a motor between the thermo fireplace and the diffuser.
• Kit Comfort Air Basic - 20 multi diffuser, 100 mm diameter ducting and a motor behind the fan.
Other optional types of diffusers can be applied depending on the kit chosen.
Refer to the relative manual inside the kit for the installation instructions.
An air intake must be installed in the place of installation in order to guarantee the air for combustion.