Installation and assembly – MCZ Vivo 80 Pellet Comfort Air - 2012 User Manual
Page 26

24
3-INSTALLATION AND ASSEMBLY
HOOD VENTILATION GRILLES
Foreword
Ventilation grilles must be set up according to how the product is placed.
If inserted in existing cladding, the ventilation grilles on the cladding will be used.
If used as a new installation, the company recommends installing the ventilation grilles as described in the following paragraph.
However, it is important to set-up 2 openings, one on the top part and the other on the lower part of the cladding.
HOOD VENTILATION GRILLES FOR NEW CLADDING
It is mandatory to install the hood ventilation grilles of the manufacturer or grilles that can guarantee the same functions
and the same air passage section.
The company cannot be held liable for any damage caused to the structure or the electrical components if this precaution
is not complied with.
The structure becomes very hot and constant and efficient ventilation must always be guaranteed inside the cladding.
This allows part of the heat of the structure to be recovered that would be lost if left inside the cladding, whilst guaranteeing perfect
product operation.
The company supplies 2 “Blade” nozzles; one is to be installed in the upper part and the other in the lower part of the cladding.
HOT CONVECTION AIR
ROOM AIR INLET
HOT CONVECTION AIR: THE HOT AIR ACCUMULATED INSIDE THE
CLADDING MUST BE LET OUT.
ROOM AIR INLET: ALLOWS AIR CIRCULATION AN OPENING MUST
BE SET-UP IN THE LOWER PART OF THE CLADDING TO ENHANCE
CONVECTION.
SUPPLIED “BLADE” GRILLE