On off, Emergency panel – MCZ Vivo 80 Pellet Comfort Air - 2012 User Manual
Page 38

D
E
ON
OFF
G
D
36
6-EMERGENCY PANEL
EMERGENCY PANEL START-UP/SHUTDOWN
If the remote control is faulty or the batteries are flat, the product can be operated in safe mode via the rear emergency panel.
In this configuration, the product can only work in manual mode and one of 3 power levels can be selected.
• APPLIANCE START-UP WITHOUT THE REMOTE CONTROL.
Switch the product on by bringing selector “D” to the ON position. The RED LED goes off upon start-up, whereas the GREEN LED starts
to flash until the start-up phase is complete. Once the product runs smoothly, the GREEN LED remains on.
• SELECTING THE POWER WITHOUT THE REMOTE CONTROL.
One of three heating powers MIN-MED-MAX can be selected (selector “E”):
The MINIMUM power corresponds to the 1 st power.
The MEDIUM power corresponds to the 3rd power.
The MAXIMUM power corresponds to the 5th power.
• APPLIANCE SHUTDOWN WITHOUT THE REMOTE CONTROL.
Switch the product off by bringing selector “D” to the OFF position.
Once the remote control is restored, remember to set selector “D” back to the “REMOTE” position, otherwise the
product will ignore the remote control commands.
SYNCHRONIZATION OF REMOTE CONTROL
Upon first start-up of the product, it may be necessary to get the stove to recognize the new remote control. To carry-out this operation,
follow the simple instructions that follow:
• connect the stove to the socket and switch the power supply button on
• ensure that the selector D of the emergency panel is in the position REMOTE
• when the first text appears onto the display of the emergency panel, press the embedded button G with the aid of a pointy object
(toothpick..)
• three flashing lines “---“ will appear on the display. Press the on/off button of the remote control for confirmation.
The three flashing lines will disappear from the display and the stove will recognise the new communication address of the remote control.
Recognition will also be confirmed by 4 acoustic sounds.
REMOTE CONTROL SYNCHRONIZATION
SWITCH-ON/OFF FROM THE EMERGENCY PANEL