2.2. Cooling and Ventilation

The 10.6 chassis does not have vent holes for conductive cooling, nor does it require any
external forced-air cooling.

2.3. Electrical Requirements

Nominal voltage 28VDC / .66 A

Max Power Consumption: 20 W

2.4. Video Connections

The 1060-001 display uses the following connectors.

Figure 2 10.6 bulkhead display connections

2.5. Pinout Connections

There are several ways to connect the remote display system

to an aircraft’s entertainment

system.

Pay close attention to the pinout descriptions on the Outline and Installation drawings to assist in
completing the wiring connections.

Note: This display is for entertainment purposes only; connect to a non-critical power bus.

3. INITIAL POWER UP

Make sure that power is turned off and perform the following steps.

1.

Ensure a low impedance ground connection on the chassis from any one of the 8-32
mounting holes.

2.

Connect the power supply and video source to the appropriate connectors.

3.

An optional, 90-degree connector kit (P/N 0300-058) allows you to route the harness
towards the back, if desired.

4.

Supply power and wait for a video signal on the screen. The default video mode is
Auto Detect and the default power mode is Auto On.

5.

The display will search for a valid video signal by priority

—Composite first and then

SDI. To use VGA, change the Operation Mode from Auto Detect to Standard
in the on-screen display (OSD).

Do not plug or unplug the display connector while power is
applied.
When cycling power, leave unit off for 20 seconds before restoring
power.