Appendix a: alarm i/o connector – PLANET ICA-HM351 User Manual

Page 76

Advertising
background image

3B

Appendix A: Alarm I/O Connector

Some features of the Camera can be activated by the external sensor that senses physical
changes in the area Camera is monitoring. These changes can include intrusion detection or
certain physical change in the monitored area. For examples, the external sensor can be a door
switch or an infrared motion detector. These devices are customer provided, and are available
from dealers who carry surveillance and security products. Electrically, they must be able to
provide a momentary contact closure.


This Camera provides wires for general I/O terminal and RS-485 interface as below:

Cable for I/O connectors:

Name

Cable Color

Function

12VDC

Brown/White

DC 12V (50mA maximum)

GND

Blue/White

GND

D+ Purple/White

RS-485

data

+

D-

Gray

RS-485 data -

DI Green/White

Digital

signal

input

DO

Orange/White

Digital signal output



User can refer to the schematic below to make a proper connection between I/O connector and
external sensor and output device.

Explanation of External I/O Circuit Diagram:

76