Troubleshooting – PLANET GST-80X Series User Manual

Page 19

Advertising
background image

- 19 -

5. TROUBLESHOOTING

This chapter contains information to help you solve issues. If the GST-80x is not functioning properly, make sure the
GST-80x was set up according to instructions in this manual.

The Power LED is not lit

Solution:

Check the power cable connection between power adapter and GST-80X.

Why I connect GST-80x to device with 1000Base-LX/SX interface and the 1000Base-LX/SX fiber con-
nection fail?

Solution:

1. Please check the fiber connection between two devices is correct.

2. Please check the 1000Base-LX / SX interface from both devices run at force full duplex mode.

3. Check and if the 1000Base-LX/SX interface of other device run at Auto-negotiation mode only,

please enable the Auto negotiation bypass function of GST-80x for successful fiber connection.


10/100/1000Base-T port link LED is lit, but the traffic is irregular

Solution:

1. Check that the attached device is not set to dedicate full duplex. Some devices use a physical or software switch

to change duplex modes. Auto-negotiation may not recognize this type of full-duplex setting.

2. Check and assure the TP ports from both GST-80x and attached device run at Auto-negotiation mode.


Advertising