You can tell the details of a warning from the (repeated) displays of the “WARNING” and “LIGHT” indicators. The

“STANDBY/ON” indicator will light up or appear blinking according to the operation mode of the projector unit. (Please

refer to ““Operation mode display”P. 75”.)
The Warning mode is activated once the message is displayed. Projection is interrupted, and the cooling fan is turned

on for about 10 seconds.
The power cannot be turned on again while cooling is in progress. Check the following after cooling is complete.

Indicator Status (Solid/Blinking)

Blinking

Frequency

Description

Check and Countermeasure

.

LIGHT

STANDBY/ON

WARNING

WARNING

(Red)

(*)

Mode

Display

x2

Cooling fan stopped abnormally

0

Check that nothing is blocking

the air inlets.

0

Check that the external

temperature is normal.

Countermeasure: Leave the unit

unoperated until it cools down.

After that, turn on the power again.

x3

Internal temperature is abnormally

high

x4

External temperature is too high

.

LIGHT

STANDBY/ON

WARNING

N

N NG

WA

LIGHT

Blinking

Simultaneously

(Red)

(Orange)

Mode

Display

x1

Abnormal circuit operation

x2
x3
x4

.

LIGHT

STANDBY/ON

WARNING

RN

WAR ING

(Red)

(Orange)

Mode

Display

G

G T

L

x1
x3
x4

When the safety switch is activated Request for repair at your

authorized dealer or a nearby

service center.

If the Warning mode is activated again, wait for the cooling fan to stop, followed by pulling out the power plug from the

outlet.

Request for repair at your authorized dealer or a nearby service center.