EMI WLHA User Manual

Page 3

Advertising
background image

www.enviromaster.com

3

WLCA/WLHA High Wall Evaporator

ControLs And ComponEnts

Continued

prodUCt dEsCription

The AmericaSeries WLCA/WLHA is

available as a (Dx) direct expansion straight

cool and heat pump. It offers a contempo-

rary design in a ductless type evaporator and

combines attractive appearance with high

efficiency conditioning for small to medium

size commercial or residential spaces. The

WLCA/WLHA is equipped with unit mounted

infrared compatible controls which also sup-

ports 24V remote wall thermostat operation.

Optional hand held remote is available.

Heat Pump models provide up to

23,000 Btuh of cooling and 20,600 Btuh of

heating. Electric heat options are available

for up to 5 kW of supplemental heat.

This American-made evaporator offers

ease of installation, operation, and service.

It can be matched with EMI’s S1CA/S1HA

09-24 and S1CA 30-36 Btuh Single-Zone

Condensing Units, the S2CA side discharge

Dual-Zone Condensing Unit, or the T2CA,

T3CA, and T4CA top discharge Multi-Zone

Condensing Units.

All EMI Air Handlers are backed by

Enviromaster International LLC and are

tested and rated in accordance with ARI
standards 210/240 and UL 1995.

Operation modes include Heat, Cool,

Dry, Fan and Auto Change-over.

Fan Operation – Auto/On. High or Low

speed fan

Fan Purge – Fan remains on for

60 seconds after Heat/Cool call is

dropped for improved efficiency (Auto

mode only)

Room air sampling: Selectable time

intervals ensure the fan will cycle

on periodically, in Auto Fan Mode

to help eliminate room temperature

stratification.

Selectable Fahrenheit (°F) or Cesius

(°C)

temperature scale.

Dry mode – Operates cooling and

electric heat simultaneously to remove

humidity. Optional electric heat must
be selected.

Anti-Short Cycle Compressor Pro-

tection.

Minimum on time for heating and

cooling

Helps eliminate room temper-

ature drop and system short cycling.

Freeze Protection – Prevents evapo-

rator freeze up

.

Test operation – Allows ease of test-

ing after installation (all timers are
eliminated).

Non-volatile back-up memory will

maintain control settings for an indefinite

period during a power outage. When

power is restored the equipment will

resume operation after a three-minute

compressor time delay.

7-day programmable with copy feature.

Filter change indicator: A timer fea-

ture indicates when the filter should be

changed according to the selected time.

Motorized supply louver with optional

sweep or six stationary settings.

Infra red compatible control allows

use of optional IR hand held controller.

note:

Unit mounted controls are

fully functional without the handheld

remote.

ControLs And ComponEnts

Note: If the control is configured for

unit mount control do NOT connect
a wall thermostat to the unit.

Large LCD Backlit Display

Single unit mounted control pack-

age

, configurable to either unit mount

or remote wall thermostat operation,

reducing model number or SKU’s
required.

Universal control can be used in

cooling only, cooling with electric heat,

heat pump, or heat pump with second

stage electric heat applications.

Operational range set point tem-

perature adjustable between 55°F and

90°F in one-degree increments.