EMI WLHA User Manual

Page 37

Advertising
background image

www.enviromaster.com

37

WLCA/WLHA High Wall Evaporator

WLCA/WLHA systEm options

notE:

Due to EMI’s ongoing development programs, design and specifications

may change without notice.

S1CA/S1HA

Side Discharge

WLCA/WLHA

S2CA

Side Discharge

CooLinG systEms WitH WALL Units

Condenser

Wall Unit

Btuh

sEEr sHr

EEr

ref.

S1CA9

WLHA09

9,000

13.0

.79

11.8

R22

S1CA2

WLHA12

12,000

13.0

.74

12.9

R22

S1CA8

WLHA24

18,000

13.0

.78

13.0

R22

S1CA4

WLHA24

24,000

13.0

.70

12.5

R22

S1CA3

WLCA36

30,000

13.0

.72

12.6

R22

S1CA6

WLCA36

33,600

13.0

.69

12.1

R22

HEAt pUmps systEm options WitH WALL Units

Condenser Wall Unit

Cooling

Btuh

Heating

Btuh

sEEr Hspf

sHr

EEr

Cop

ref.

S1HA9

WLHA09

9,000

8,200

13.0

7.7

.75

12.0

3.6

R22

S1HA2

WLHA12

12,000

10,200

13.0

7.7

.73

11.1

3.4

R22

S1HA8

WLHA24

18,000

16,400

13.0

7.7

.73

12.1

3.8

R22

S1HA4

WLHA24

23,000

20,600

13.0

7.7

.71

11.9

3.5

R22

CooLinG systEms WitH s2CA sidE disCHArGE

Wall Unit (s)

Condenser

Btuh

sEEr

sHr

EEr

ref.

WLHA09

S2CA99

18,000

13

.80

11.9

R22

WLHA12

S2CA22

23,000

13

.72

12.4

R22

WLHA09+WLHA12

S2CA92

21,000

13

.72

12.0

R22

Advertising