4. Troubleshooting (DeviceNet)

♦ Causes of Error

Possible Cause

Examination Method

Countermeasure

{ Disconnected

terminating resistors

{ Cable disconnection
{ Disconnected

connector

{ Disconnected signal

wire

(1) Check that terminating

resistors are connected to
both ends of the network.

(2) Measure resistance between

signal wires with
communications power
supply OFF.

→ Normal: 50 to 70

z Measuring point: Connection

of the problem unit

z For detail, refer to the section

4.1.3.1 Connection Problem.

Fix the problem.

How to find the trouble
point:
Remove the terminating
resistor on one end of the
network. The trouble point
is where resistance
changes from 120

Ω.

{ Loose connector
{ Loose signal wire

Check for the connection of
connectors and signal wires.
→ The connectors and signal

wires should be firmly
connected.

z Checkpoint: all nodes and all

branch taps

z For details, refer to the section

4.1.3.2 Loose Connector and
Signal Wire
.

Connect the connectors
and signal wires again.

{ Voltage drop of

communications
power supply

Measure voltage of
communications power supply at
the trouble unit.
→ Normal: 11V or more between

V+ and V-

z If the voltage is 11 to 14 V, the

unit is a possible cause. Fix the
problem on the unit.

Check the voltage of the
power supply.
Calculate the current
capacity of the cable and
add more communications
power supplies.

{ Noise

(external cause)

Check the noise intrusion via the
following paths (1) to (3).
(1) Noise via DRAIN (FG)
(2) Induced noise via

communication cable

(3) Communications power

supply

→ For details, refer to the section

4.1.3.3 Noise Intrusion.

Take countermeasures
against noise.

{ Broken unit

Replace the broken unit with a
new one.
→ Verify whether the problem is

fixed.

Replace the unit with a
new one.

z No cause is

identified.

Identify the trouble point by
dividing the network.
→ For details, refer to the section

4.1.3.4 Broken Unit
Examination
.

88