Epson 811p User Manual

Page 71

Advertising
background image

Maintaining and Transporting the Projector

65

Follow these steps to replace the lamp:

1. Turn off the projector, wait for it to cool down (when the light

stops flashing), then unplug the power cord.

2. Allow the projector to cool for at least half an hour (if it has been

on).

3. Use a screwdriver to slide the latch and pop open the lamp cover.

Then lift up and remove it.

4. Use a screwdriver to loosen the two silver screws holding the lamp

in place. (You can’t remove these screws.)

warning

Let the lamp cool before
replacing it. If the lamp
breaks, handle the shards
carefully to avoid injury.

600-811-820.book Page 65 Tuesday, April 30, 2002 10:17 AM