Figure 13. venting with three 90° elbows – Heat & Glo Fireplace 6000 XLT User Manual

Page 18

Advertising
background image

15

VENTING WITH THREE (3) 90° ELBOWS

V (FT.)

H (FT.) (8000 & 6000’s)

H (FT.) (SL-42DVT)

1' MIN. (305 mm)

6' MAX. (1.86 m)

3' MAX. (914 mm)

2' MIN. (610 mm)

12' MAX. (3.72 m)

6' MAX. (1.86 m)

3' MIN. (914 mm)

18' MAX. (5.58 m)

9' MAX. (2.74 m)

4' MIN. (1.22 m)

24' MAX. (8.44 m)

12' MAX. (3.66 m)

24' MAX. (8.44 m)

12' MAX. (3.66m)

NOTE: H + H1 MAX. 24' (8.44 m) (8000 & 6000’s)

NOTE: H + H1 MAX. 12' (3.66 m) (SL-42DVT)

V + V

1

MAX. 20' (6.2 m)

H

1

H

1

H

V

1

V

1

V

NOTE: MODEL 6000 ARCH

A 12-inch length of straight vent pipe MUST be
the first vent component attached to the unit.