Step 6 the gas supply line – Heat & Glo Fireplace 6000 XLT User Manual

Page 32

Advertising
background image

29

Figure 28. Gas Controls Systems

Step 6
The Gas
Supply Line

NOTE: Have the gas supply line installed by a
qualified service technician in accordance with all
building codes
.

NOTE: Before the first firing of the fireplace, the
gas supply line should be purged of any trapped air.

NOTE: Consult local building codes to properly size
the gas supply line leading to the 1/2 inch
(13 mm) hook-up at the unit.

This gas fireplace is designed to accept a 1/2 inch
(13 mm) gas supply line.

To install the gas supply line:
• A listed 1/2 inch (13 mm) manual shut-off valve and a

listed flexible gas connector are connected to the 1/2
inch (13 mm) inlet of the control valve.

• A 1/8 inch (3 mm) N.P.T. plugged tapping, accessible

for test gauge connection, should be provided for in
the gas supply line leading to the unit’s shut-off valve.

• Locate the gas line access hole in the outer casing of

the fireplace.

• Open the fireplace lower grille, insert the gas supply

line through the gas line hole, and connect it to the
shut-off valve.

• When attaching the pipe, support the control so that

the lines are not bent or torn.

• After the gas line installation is complete, use a soap

solution to carefully check all gas connections for
leaks.

WARNING
DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS
.

3/16" (5 mm)

DSI IGNITION

IGNITOR

1/2" (13 mm)

1/2" (13 mm)

STANDING PILOT

3/8" (10 mm)

Advertising
This manual is related to the following products: