Caution, For direct spark ignition (dsi) wiring, Figure 31. fan wiring diagram – Heat & Glo Fireplace 6000 XLT User Manual

Page 35

Advertising
background image

32

NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 DEGREE C
RATED WIRE.

NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 DEGREE C
RATED WIRE.

BLOWER

BLOWER RECEPTACLE

JUNCTION BOX

VARIABLE SPEED CONTROL

TEMPERATURE
SENSOR SWITCH

TEMPERATURE
SENSOR SWITCH

GROUND

WHT

BLK

BLK

GRN

WHT

BLK

BLK

BLK

BLK

BLK

BLK

BLK

110-120 VAC

BLK

WHT

FAN WIRING DIAGRAM

Figure 31. Fan Wiring Diagram

For Direct Spark Ignition (DSI) Wiring

Appliance Requirements
This appliance requires that 110-120 VAC be wired to
the factory installed junction box. Maintain correct
polarity when wiring the junction box.

Optional Accessories
Optional fan and remote control kits require that 110-
120 VAC be wired to the fireplace junction box.

Remote Wall Switch
Position the remote wall switch in the desired position
on a wall. Run a maximum of 25 feet
(7.8 m) or less of 16 A.W.G. minimum wire and
connect it to the fireplace ON/OFF switch pigtails.

NOTE

Electrical wiring must be installed by a licensed
electrician.

CAUTION

LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.