B. Installing Vent Components

1. Attach the First Vent Component to the

Starting Collars

To attach the first vent component to the starting
collars of the fireplace:

• Apply a 3/8 inch (9.5 mm) bead of stove cement

around the inner pipe fireplace starting collar.

• Make sure that the fireplace rope gasket supplied

with the fireplace seals between the first
vent component and the outer fireplace wrap.

• Lock the vent components into place by sliding the

concentric pipe sections with four (4) equally
spaced interior beads into the fireplace collar or
previously installed component end with four (4)
equally spaced indented sections.

• When the internal beads of each outer pipe line up,

rotate the pipe section clockwise about one-quarter
(1/4) turn. The vent pipe is now locked together.

• The first 90° elbow installed in the vent system of a

rear venting fireplace MUST BE in a vertical posi-
tion.

1. Apply the stove ce-

ment.

2. Line up the internal

beads and rotate the
pipe sections clock-
wise until locked.

3. Lock the vent compo-

nents into place.

4. Check the seal on the

rope gasket.

Figure 15. Attaching the First Vent Component to

the Starting Collars

WARNING
A 3/8 INCH (9.5 MM) BEAD OF STOVE
CEMENT MUST BE PLACED AROUND
THE INNER PIPE FIREPLACE
STARTING COLLAR BEFORE
ATTACHING THE FIRST VENT
COMPONENT. FAILURE TO SEAL THIS
JOINT MAY CAUSE THE FIREPLACE TO
OPERATE IMPROPERLY. SEE THE
DIAGRAM .

STARTING
COLLAR

STARTING
COLLAR

FIRST
VENT
COMPONENT

FIRST
VENT
COMPONENT

STOVE
SEALANT
BEAD
3/8" (9.5 mm)

STOVE
SEALANT
BEAD
3/8" (9.5 mm)

1 INCH (25.4 mm)

3/8 INCH (9.5 mm)