Step 5 the gas control systems – Heat & Glo Fireplace 6000 XLT User Manual

Page 31

Advertising
background image

28

The diagram below shows how to properly position,
level, and secure the fireplace.

1. Place the fireplace

into position.

2. Level the fireplace

from side to side and
from front to back.

3. Shim the fireplace

with non-combus-
tible material, such
as sheet metal, as
necessary.

4. Secure the fireplace

to the framing by
nailing or screwing

Figure 27. Proper Positioning, Leveling, and

Securing of a Fireplace

Step 5
The Gas Control
Systems

WARNING
THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.

Two types of gas control systems are used with
these models:

Standing Pilot Ignition and Direct

Spark Ignition (DSI). Model 6000XLT has Standing
Pilot Ignition only. Model 6000ARCH has DSI only.

Standing Pilot Ignition System
This system includes millivolt control valve, standing
pilot, thermopile/thermocouple flame sensor, and
piezo ignitor.

WARNING
110-120 VAC MUST NEVER BE
CONNECTED TO A CONTROL VALVE
IN A MILLIVOLT SYSTEM.

Direct Spark Ignition (DSI) System
This system includes a 24V control valve, electronic
module, transformer, and spark ignitor/flame sensor.

WARNING
110-120 VAC MUST BE WIRED TO THE
FIREPLACE JUNCTION BOX IN A DSI
SYSTEM.

WARNING
DIRECT VENT PROPANE MODELS
WITH DSI CONTROL SYSTEMS
CANNOT BE USED IN CANADA.

Step 4
Positioning,
Leveling, and
Securing the
Fireplace

Advertising