DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide

4


You can also use other Combiner or Mixer-Splitter with HP-51M to build the same system, see the following

Figure

3

for different cabling,

Figure 3: Different Cabling of HP-51M

NOTE: After power up HP-51M, the led ‘SynMode’ will always be glowing, and led ‘Link/Act’ will light up for at
least one EP is detected on the HCNA network. A dimmed led ‘Link/Act’ shows no EP attached to the HCNA
network.

NOTE: The minimum attenuation between Master and EP is 12dB. EP is usually connected to the coaxial cable via
a Tap device that provides enough attenuation (contributes more than 20dB). If you intend to connect the Master
and EP directly for test purpose, please add the attenuator that exceeds 12dB to the coaxial cable.

Verification

After you have finished the installation, you should be able to access HP-51M through Ethernet link or through
HCNA
link (via Host PC behind EP) to verify the installation is completed. (See next Chapter for details).