Caution, K. class a metal chimney – Heat & Glo Fireplace Heat & Glo PALOMA-BZ-MOD User Manual

Page 20

Advertising
background image

Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12

20

K. Class A Metal Chimney

Figure 5.20

1. Remove existing chimney cap.

2. Measure the distance from the top of the chimney to

the bottom of the ceiling support box, add 3 in. (76
mm) to this measurement, and cut a section of 4 in.
(101 mm) flex pipe to that length (the flex should be
fully extended).

3. Connect the end of the flex pipe section to the

underside of the top adapter, using four sheet metal
screws (Figure 5.21).

SHEET METAL SCREWS

FLEX PIPE

TOP ADAPTER

Figure 5.21

Ensure that existing chimney is functionally sound and
clean.

• Have inspection done by qualifi ed chimney sweep or

professional installer BEFORE converting to direct vent
appliance.

CAUTION

FLASHING

4 in. (102 mm)

FLEX PIPE

RETRO CONNECTOR

DIRECT VENT

PIPE

EXISTING METAL

CHIMNEY SYSTEM

TOP ADAPTER

TERMINATION

CAP PART #SLK-991DA

Figure 5.18

6. Place the support clamp (provided with the support

box) inside the support box (at the bottom), and secure
to the pipe section. The clamp allows the support box
to support the weight of the pipe sections. Continue to
add pipe sections until you are above the roofline.

7. Complete the cathedral ceiling installation by following

the same procedures outlined in steps 7 through 9 for
vertical installations, pages 17-18.

8. Install the black trim collar around the outside of the

cathedral ceiling support box (Figure 5.19). The two
pieces of the trim collar slide over one another to allow
for easy adjustment around the support box. Using the
six screws provided, secure the four corners and the
overlapping sections of the trim collar to the ceiling.
You may want to predrill the holes for the overlapped
sections for ease of installation.

CATHEDRAL CEILING
SUPPORT BOX

TRIM COLLAR

SCREWS

Figure 5.19

Advertising