Caution, Warning caution, D. loss of power and battery backup usage – Heat & Glo Fireplace Heat & Glo PALOMA-BZ-MOD User Manual

Page 29: Battery location, Unplug when using batteries

Advertising
background image

29

Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12

Figure 7.2

NOTE: Appliance will not operate
unless properly grounded.

*

TRANSFORMER

3 VAC

PLUG IN

VALVE

GROUND TO

APPLIANCE CHASSIS

PIGGYBACK

ON/OFF SWITCH

INTERMITTENT
PILOT IGNITOR

IGNITION MODULE

3 VAC

I

S

WHT

ORG

RED

ORG

BRN

GRN

BRN

BLACK

BATTERY

PACK

GROUND

REMOTE

CONTROL

HOT

NEUTRAL

VALVE

PLUG-IN 3V

TRANSFORMER

ON/OFF

WALL

SWITCH

IGNITION

MODULE

(3V)

FLAME

SPARKER/SENSOR

JUNCTION BOX

BATTERY LOCATION

Unplug when
using batteries

Figure 7.3

D. Loss of Power and Battery Backup Usage

1. Disconnect the power supply.

2. Remove the front door assembly and lower access

panel.

3. Place two "D" cell batteries into the battery holder.

(Figure 7.3)

4. Turn on appliance and verify it is operational.

5. Replace lower access panel and front door assembly.

CAUTION

Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.

Shock hazard.

• Replace damaged wire with type 105º C rated

wire.

• Wire must have high temperature insulation.

WARNING

CAUTION

If IPI battery back-up is installed:

• Do not install batteries if the backup mode may not be used

for extended time.

• Batteries may leak.

• Install batteries only when needed for power outage.

Advertising