HIGH WIND TERMINATION

CAP #SLK-991DA

TOP ADAPTOR

THREE SHEET

METAL SCREWS

FLASHING

9. Attach the flex to the retro connector. Use three sheet

metal screws to attach the flex liner to the connector
(Figure 5.29). Mount the retro connector to the
masonry wall using masonry bolts. Redrill larger holes
on connector as needed. Be careful to ensure that the
connector is centered in the opening and the mounting
holes line up with the masonry wall.

6 in. (152 mm) DIAMETER

OPENING IN MASONRY WALL

RETRO

CONNECTOR

THREE MASONRY BOLTS

(NOT INCLUDED)

FOUR MASONRY BOLTS

(NOT INCLUDED)

RETRO

CONNECTOR

WALL

THIMBLE COVER

10. Slide wall thimble cover over retro connector and

secure with masonry bolts (Figure 5.30). If you have
a framed wall in front of the masonry, use wood
screws to mount wall thimble cover to framed wall,
over retro connector and 10 in. (254 mm) square
framed opening (Figure 5.25). If needed, add a
section of direct vent pipe to the retro connector
in order to extend through the opening in the wall
thimble cover.

Figure 5.28

Figure 5.29

Figure 5.30

11. The connection between the appliance and the retro

connector may be completed with sections of direct
vent pipe.