Setup

25

Configuring Supported Devices

HP Surestore Director FC-64 Switch

The FC 16B switch can be used with the HP Surestore Director FC-64
switch. Specific configurations must be set on both devices to make this
work.

On the FC 16B, logon to the switch with administrative privileges and enter
the following telnet commands:

1.

switchDisable

2.

interopMode 1

3.

switchEnable

On the Director FC-64 switch, the following steps must be completed to
configure the switch for interoperability:

Step 1: Verify Unique Domain IDs
Step 2: Select a Single Surestore FC-64 Director as Principal Switch
Step 3: Verify Unique Zone Names
Step 4: Verify Brocade Product Zoning Configurations
Step 5: Verify Zone Naming Conventions
Step 6: Verify Operating Mode
Step 7: Verify Surestore FC-64 Director Switches’ Operating
Parameters
Step 8: Verify Firmware Version
Step 9: Verify EFC Manager Version
Step 10: Verify Private Loop Targets on Brocade Products are
Translated to Fabric
Step 11: Add Switches to Fabric
Step 12: Complete Zoning Activities
Step 13: Save Active Zone Set

For complete instructions on configuring the HP Director FC-64 switch see
“Checklist for Merging Fabrics” in the Merging Heterogeneous Fabrics
Instructions
white paper on the FC 16B documentation CD-ROM.