HP 1Gb/2Gb switch 16B A7340-96002 User Manual

Page 32

Advertising
background image

26

Quick Start Guide

HP Surestore VA 7400

The FC 16B also can support a 2Gb connection to an HP Surestore Virtual
Array 7400. Set the port speed to 2Gb using the telnet command

portCfgSpeed

.

Use the Virtual Front Panel (VFP) on the VA 7400 and configure the device
as follows:

1. Change the controller port data rate to 2 Gbits/s

a. To change the port data rate to 2 gigabits/second for controller 1, enter:

vfpmgr -S 2 -c 1

When prompted to reset, enter

no

.

b. To change the port data rate for controller 2, enter:

vfpmgr -S 2 -c 2

When prompted to reset, enter

no

if additional settings must be

changed. If all changes have been made, enter

yes

to reset the array.

2. Change the controller port topology.

a. To change the port topology for controller 1 enter the following

command, selecting

4

for Direct Fabric Attach:

vfpmgr -t 4 -c 1

When prompted to reset, enter

no

.

b. To change the port topology for controller 2 enter the following

command, using the same topology value used for controller 1:

vfpmgr -t 4 -c 2

When prompted to reset, enter

no

if additional settings must be

changed. If all changes have been made, enter

yes

to reset the array.

Private Loop Devices

To work with private loop devices such as the FC 60, the FC 10, or the
SCSI bridge FC 4/2, set the FC 16B switch port as an L_PORT. See the
telnet command

portCfgLport

.